working time - Pret oferta
-
Sursa alimentare fara carcasa 12V 3A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 1200ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 50ms/230VAC 10ms.... Working temp.: -20 ~ +65C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 12V 5.2A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 13.5V 3.3A
tolerance: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time...: 800ms, 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90... recover. Working temp.: -10 ~ +60C (Refer to output load derating curve) Working ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 15V 2.4A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 1200ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 50ms/230VAC 10ms.... Working temp.: -20 ~ +65C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 15V 3A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 15V 4.2A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 24V 0.625A
: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 5 ~ 24V:1200ms, 30ms 48V:1200ms..., 75ms at full load Hold up time (Typ.): 100ms at full load Voltage range: 85... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 24V 1.5A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 1200ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 50ms/230VAC 10ms.... Working temp.: -20 ~ +65C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 24V 1.9A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 24V 2.7A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 27V 2.4A
: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 48V 1.35A
tolerance: +/- 2.0% Line regulation: +/- 1.0% Load regulation: +/- 2.0% Setup, rise time...: 800ms, 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90... recover. Working temp.: -10 ~ +60C (Refer to output load derating curve) Working ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 5V 12A
: +/- 3.0% Line regulation: +/- 1.0% Load regulation: +/- 3.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 5V 2.8A
% Load regulation: +/- 1.0% Setup, rise time: 5 ~ 24V:1200ms, 30ms 48V:1200ms, 75ms... at full load Hold up time (Typ.): 100ms at full load Voltage range: 85 ~ 264VAC... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA -
Sursa alimentare fara carcasa 5V 8A
: +/- 3.0% Line regulation: +/- 1.0% Load regulation: +/- 3.0% Setup, rise time: 800ms..., 30ms at full load Hold up time (Typ.): 60ms at full load Voltage range: 90 ~ 264VAC.... Working temp.: -10 ~ +60C (Refer to output load derating curve) Working humidity: 20 ..
Electrice
Diverse
VEZI OFERTA
Index oferta: 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z